-40%

3M 60923 Organic Vapor Acid Gas Replacement Resp Cartridge Filter 1 Pair

$ 24.28

Availability: 82 in stock
  • Country/Region of Manufacture: United States
  • Modified Item: No
  • MPN: 7000029640
  • UPC: 0051138464677
  • Expiration Date: 2025
  • Mask Size: M
  • Condition: New
  • Bundle Description: 1 Package of 2 Individual Cartridges
  • Facial Coverage: Half Mask
  • Model: 6000 Series
  • Custom Bundle: Yes
  • Brand: 3M

    Description

    Brand New
    3M 60923 Organic Vapor Acid Gas Replacement Resp Cartridge Filter 1 Pair
    NEW AND SEALED
    SAME DAY SHIPPING, SHIP FROM MID-WEST USA, Made In USA
    Expiration
    Date 2025
    This liquidation sale Proceeds will be used to
    help struggling small businesses during the current national crisis.
    NIOSH-approved for protection against mercury vapor, chlorine, sulfur dioxide, organic vapor and hydrogen sulfide
    NIOSH-approved P100 particulate filter for respiratory protection against certain oil and non-oil based particulates
    Bayonet connection style for compatibility with many 3M half and full facepiece respirators
    Swept-back design for enhanced field of view and comfort
    3M 60923 Organic Vapor/Acid Gas Replacement Respirator Cartridge/Filter, 1 Pair
    Specifications
    Brand
    3M™
    Connection Type
    Bayonet
    Net Weight (Metric)
    123 g
    NIOSH Cartridge or Filter Assigned Color Coding
    Magenta/Olive
    Product Series
    6000
    Product Type
    Cartridge
    Recommended Application
    Chemical Transfer
    , Laboratories
    , Line Opening
    Recommended Industry
    Chemicals
    Standards/Approvals
    NIOSH Approved
    Details
    NIOSH-approved for protection against mercury vapor, chlorine, sulfur dioxide, organic vapor and hydrogen sulfide
    NIOSH-approved P100 particulate filter for respiratory protection against certain oil and non-oil based particulates
    Bayonet connection style for compatibility with many 3M half and full facepiece respirators
    Swept-back design for enhanced field of view and comfort
    P100 particulate filter is permanently attached to cartridge for easy, one-step assembly
    Wide range of applications reduces inventory needs
    For workplace/occupational use only
    Package contents: 1 case contains 30 pairs of cartridges (60 each)
    3M™ Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927 is NIOSH-approved for protection against mercury vapor, chlorine, sulfur dioxide, organic vapor and hydrogen sulfide. These cartridges are compatible with the 3M half and full facepiece respirators with a bayonet-style filter/cartridge connection.
    Designed to enhance field of view and comfort on the job, these cartridges/filters feature a low-profile, swept-back design. The 3M

    Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927 is easy to install and compatible with many 3M half and full facepiece respirators including the 3M

    Half Facepiece Reusable Respirators 6000, 6500/6500QL, and 7500 Series, and the 3M

    Full Facepiece Reusable Respirators 6000, FF-400, and 7800 Series, helping to reduce inventory needs.
    The 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927 helps provide protection against mercury vapor, chlorine, sulfur dioxide, certain organic vapors and hydrogen sulfide and particulates in a variety of environments. Recommended applications for the cartridge include chemical transfer, laboratories, and line opening. It is commonly used in industries such as chemicals, mining, oil and gas, pharmaceuticals, and primary metals.After you've determined the contaminants and exposure levels in your work environment, help protect your employees with a properly selected, fitted, and used 3M

    Reusable Respirator and corresponding cartridges. 3M

    Combination Cartridges/P100 Particulate Filters are NIOSH-approved and help provide respiratory protection from certain vapor and/or acid gas and particulate concentrations up to 10 times (10x) the OSHA Permissible Exposure Limit (PEL) with half facepiece respirators and 50 times (50x) the OSHA PEL with quantitatively fit tested full facepiece respirators. Not for use in environments that are immediately dangerous to life or health (IDLH).Change 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927 within 50 hours of exposure to mercury vapor, in accordance to your well-documented change-out schedule, or earlier if smell, taste, or irritation from contaminants is detected. Replace the cartridges/filters if they become damaged or if breathing becomes difficult. If used in environments containing Change 3M Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter P100 60927 within 50 hours of exposure to mercury vapor, in accordance to your well-documented change-out schedule, or earlier if smell, taste, or irritation from contaminants is detected. Replace the cartridges/filters if they become damaged or if breathing becomes difficult. If used in environments containing